datasheets.com EBN.com EDN.com EETimes.com Embedded.com PlanetAnalog.com TechOnline.com  
Events
UBM Tech
UBM Tech

Design Article

Managing power in capacitive touch sensing applications, Part 1

Vibheesh B, Cypress Semiconductor

3/15/2013 3:12 AM EDT

Use sleep mode and optimize the sensor report rate

Report rate and sleep mode work together to define how the capacitive touch sensors are sampled, as shown in Figure 2. Report rate defines how often the sensors are sampled by the A-to-D converter. When a sensor is sampled, the capacitive sensing controller is in active mode. When a sensor is not being sampled, the controller can be put into sleep mode. In sleep mode, the controller powers down all internal blocks and peripherals. This mode is supported by most of the capacitive sensing controllers on the market.


Figure 2: Sensor sampling with sleep mode
Click on image to enlarge

Selecting a low report rate and a longer sleep time are the keys to reducing the average power consumption. Report rate and sleep mode directly affect the capacitive sensing controller’s average current consumption, as defined in Equation 1.


Equation 1: Average current calculation

Where:
IActive = Current consumed by the controller when it is sampling a sensor
TActive = Time it takes the controller to sample all of the sensors
ISleep = Current consumed by the controller when it is in sleep mode
TSleep = Amount of time the controller remains in sleep mode

As a general rule of thumb, a human finger cannot touch a button faster than 150 ms. Typical A-to-D conversion times range from 200—6000 µs. This means that several A-to-D conversions can be performed during the 150 ms a sensor is being touched. Optimize the report rate for your specific A-to-D conversion time.

Reducing CP helps to reduce TActive because the controller can use a lower A-to-D converter resolution. Selecting a capacitive sensing controller with lower active current reduces IActive. Keep in mind that sleep mode current has a minimal impact on the average current.




dushyant

3/21/2013 11:56 PM EDT

Hi, Article details about the management of activities to enhance battery life but didn't discuss the details of the measurement of capacitance which the most critical part of this technology. Measurement of C using A/D is not straight forward & needs a lot of consideration to avoid false or no key detection.

Sign in to Reply



reuben

3/24/2013 1:14 PM EDT

Thanks for an interesting article. By how much these power management techniques could lower the power consuption? Would a lower capacitive power consumption be on a par with Infra Red touchscreens?

Sign in to Reply



reuben

3/28/2013 1:41 PM EDT

When to expect the article part2? Would it address my two questions (above)?

Sign in to Reply



Please sign in to post comment