Breaking News
News & Analysis

Fab Fire Causes DRAM Price Surge

9/6/2013 07:40 AM EDT
16 comments
NO RATINGS
More Related Links
View Comments: Newest First | Oldest First | Threaded View
Page 1 / 2   >   >>
goafrit
User Rank
Manager
Re: An investigation
goafrit   9/12/2013 8:47:29 AM
NO RATINGS
>> I don't believe the fire was started by a Marine.  I think it was a paint contractor who wanted to leave work early. 

Very bad for the marine though. He gets decades behind bar.

MClayton0
User Rank
CEO
Old Fab Fires and Accidents
MClayton0   9/9/2013 4:36:36 PM
NO RATINGS
Silane Gas fires/furnace explosions were so common that Japan banned the gas for many years. Hydrogen gas was not explosive usually but it did burn, often on purpose to make water vapor in oxidation tubes.  

From 1960 to 2000 I can remember four small fires personally, and one HCl gas leak at National Semiconductor in new fab, that destroyed most of the control systems in all the process tools, as a regulator blew and an entire cylinder of HCl gas filled a new closed clean room.  Those that saw it first, said it was like a white cloud along the floor (heavy, but trapped in the room overnight, eating away the systems).  Anyone from National remember that story??

One TEOS fire in furnace was due to a technician's installation of the TEOS bubbler with the tubing hooked up backwards, so instead of argon bubbling through the liquid TEOS sending small vapor into the hot tube to grow oxide on wafers, the LIQUID was suddently pushed into the tube, blowing off the end-cap, and melting tubing, with the flames shooting from a waving tube while a tech tried to put out the fire (instead of waiting a few more seconds for the TEOS to run out) with an ancient fire extinguisher.....which dumped sodium all over the diffusion area (1962 as I remember, at Westinghouse fab in Elkridge MD.)   Managers watched in horror through the clean room windows.   

Many other fires were common in early epitaxial deposition systems where hydrogen was used.   Famous diffusion gas story from transistor days in Connecticut:  Arsenic diffusion furnace was outdoors, under tin roof.   At end of furnace, manager notice a pile of dead flies on ground.  The rest of the story has many versions.

From the days when we built most of our own equipment, at least the gas systems added to various furnaces, and the early days of plasma etching with nasty gases and vacuum pump corrosion issues, and crazy attemps at trapping the nasty gas byproducts, many maintenance techs were hospitalized.  Bell Labs finally put out a paper on the very dangerous byproducts of plasma reactions.  Very long story also about photoresist chemicals impacting pregnant women, and I personally remember washing my hands in tricholoethylene to get the negative resist off...before it was banned.    We were a dangerous bunch for a long time.

Daryl.H
User Rank
Rookie
Re: An investigation
Daryl.H   9/9/2013 1:33:53 PM
NO RATINGS
I don't believe the fire was started by a Marine.  I think it was a paint contractor who wanted to leave work early. 

NAND_analyst
User Rank
Rookie
Re: An investigation
NAND_analyst   9/8/2013 10:54:41 PM
NO RATINGS
Capacity was already strained in DRAM. Apple said in their last CC that they expected DRAM prices to rise in the second half of the year. Both mobile DRAM and NAND are growing nicely, PC DRAM capacity has been diverted to those two segments of memory chips.


Unlike in the past, there is not any slack capacity in memory these days. Too many companies have gone out of business or have shrunk to niche players, and it costs way too much and takes too much technological expertise at the smaller process nodes that state of the art production requires to just throw up new fabs.

goafrit
User Rank
Manager
Re: An investigation
goafrit   9/8/2013 5:53:44 AM
NO RATINGS
>>  The weakness in any fab will always be people. Even with training, people make mistakes and do things with significant consequences

Fire cause problem in any situation and human beings can be blamed. Few years ago, a U.S. marine caused fire in a submarine that they need nearly a $1B to fix. The guy goes to jail while the Navy loses a warship. The problem with humans is that no one treats its well until it shows that it is the most important element in any business. You build a fab of $2B, you pay the worker min wage!

goafrit
User Rank
Manager
Re: An investigation
goafrit   9/8/2013 5:50:17 AM
NO RATINGS
>> Anyways, why the price has to go up...do the other companies cannot make up for this gap in Hynix production? 

That is my thinking. Unless we are not elastic in capacity buildup. There needs to be a way for other firms to step up and take advantage of the evolving opportunity this presents.

goafrit
User Rank
Manager
Re: An investigation
goafrit   9/8/2013 5:48:33 AM
NO RATINGS
>>  Better pay for a couple good fab experts, too, though.

Not the best idea - better ask them to get funds as other market-force operating entities do.

goafrit
User Rank
Manager
Re: An investigation
goafrit   9/8/2013 5:38:44 AM
NO RATINGS
>> Safety conditions in China fans may be worth looking into

Should not be a problem. If they operate on market forces, they will go bankrupt. The problem is that they get free money and that is why we need to "look into" their operations. If you can afford $1B to build a fab, it makes sense you can at least mitigate fire risk

BOMBOVA
User Rank
Manager
By Chance betting on the downside
BOMBOVA   9/8/2013 12:29:46 AM
NO RATINGS
i purchased ten trays of 8 Gbyte, n 16 Gbyte ECC memory for servers.  "inJune of this year" ,    well,  to my surprise,    the close of this week,  i am getting offerings from server builders, a 25 percent premium on my offerings.     Needless to say, what a quick reaction to a fire, this industry capitulates to.  

Sanjib.A
User Rank
CEO
Re: An investigation
Sanjib.A   9/7/2013 10:15:19 PM
@m00nshine: Thank you for sharing the knowledge. I have not visited a single fab yet and my comment was based on the assumptions that I did not think that the probability of occurrences of hazards in a semiconductor fab might be as severe as the same in the industries such as Oil refineries/off-shore platforms, where installing SIL2/3 rated safety systems is a regulatory requirement. You are correct, cost of lives (and properties) in case of an accident is much much more than cost of installing "costly" safety systems. I am interested to know which are the typical applications for the safety systems installed in fabs? for protection against toxic gas leakage & fire? Are there any standards to follow?

Page 1 / 2   >   >>
Flash Poll
Radio
LATEST ARCHIVED BROADCAST
EE Times editor Junko Yoshida grills two executives --Rick Walker, senior product marketing manager for IoT and home automation for CSR, and Jim Reich, CTO and co-founder at Palatehome.
Like Us on Facebook

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
EE Times on Twitter
EE Times Twitter Feed