datasheets.com EBN.com EDN.com EETimes.com Embedded.com PlanetAnalog.com TechOnline.com  
Events
UBM Tech
UBM Tech

Weird and Wacky Engineering

Engineering disasters: the Indiana stage collapse

Brian Fuller

8/15/2011 6:55 PM EDT

Five people were killed and at least 45 concert-goers injured when a scaffolding blew over in 70 mph winds at the Indiana State Fair this weekend.

Audience video captures the horror:




Already, engineers are buzzing over how this tragedy could have been prevented. Such scaffoldings are commonplace and designed, apparently, to withstand gusts up to 90 mph. There are always tradeoffs between weight, costs, safety and usability.

And as investigators sift through the wreckage, clues could emerge suggesting defective joints, missing bolts, fatigued metal or other possible causes.

If you were tasked with developing the next-generation scaffolding that needed to stand up in hurricane-force winds, how would you do it in a practical, cost-effective way?





 




Work to Ride comma Ride to Work

8/16/2011 3:52 PM EDT

I think that is an unreasonable requirement or expectation for temporary structures. Mitigation through evacuation. We'll have to see what the investigation reveals but one change that might have prevented the collapse would be to ensure the covering would "sacrifice" itself and fly off to reduce the wind loads on the rest of the structure. Unfortunately, the engineer loses control of the structure once it leaves the factory and there are any number of (unapproved or unintended) things that the end users will do with these. Given enough time or money you can do almost anything. Question is, will someone want to pay for it?

Sign in to Reply



brian_g

8/18/2011 12:28 PM EDT

That is a good idea. Maybe they could have flags at the top of the structure that are weighted so that they only unfurl at winds above a certain speed, or a small sensor that sounds an alarm. I suppose those aren't complete solutions, but just a start.

Sign in to Reply



mseekins

8/16/2011 4:20 PM EDT

It was reported that the NWS issued a high wind warning only 10 minutes before the disaster. In my part of the country these warnings are typically not issued until the weather event is directly overhead. Maybe a little less reliance on computer models and more human judgement at the NWS offices could get these warnings out sooner.

Sign in to Reply



Robotics Developer

8/16/2011 5:00 PM EDT

Given the exposed nature of the stage at the fair it would be hard to protect it and fair goers from injury/damages. I wonder what type of connection with the ground was made? What if the structure was reinforced with strong guy wires that both held it down in place and prevented side to side swaying? I was wondering what (if any) covering was on the top structure of the staging; if it looked like an airfoil to the winds then there could be a unintended set of stresses on the structure. Given the temporary nature and the possible onsite setup/assembly it is possible that the best engineered structure would not survive high winds (if for example the right number and type of connectors were not used). Just wondering, my heart goes out to those who lost loved ones and to those recovering.

Sign in to Reply



Thomas "Rick" Tewell

8/16/2011 5:38 PM EDT

ummm...is this EE related?

Sign in to Reply




Thomas "Rick" Tewell

8/17/2011 11:58 AM EDT

Nope. Just thought since it was under "EE Life" it might ought to be. This wasn't really a blog entry either...so...just sayin'.

Sign in to Reply



seaEE

8/17/2011 1:32 AM EDT

Dashpots, springs, and weights can be modeled electrically. Can a truss be modeled electrically?

To what extent could a structure like this be scaled down and subjected to wind tunnel tests? Also, with the continued miniaturization of sensors, it seems with some structures you might be able to create a network of stress sensors and start taking data on the forces they are subjected to.

Sign in to Reply



rmalone2

8/17/2011 11:52 AM EDT

Guy anchors can be setup quickly and economically and have proven themselves reliable in stabilizing countless numbers of guyed antenna towers in hurricane affected regions.

Sign in to Reply



Work to Ride comma Ride to Work

8/18/2011 12:48 PM EDT

But most antenna towers do not have dozens of square yards of "sails" attached to them either.

Sign in to Reply



agk

8/19/2011 6:17 AM EDT

I feel this stage is built by freshers. The experts look for all these kind of troubles before hand and give provisions to handle these situations safe to the lives.

Sign in to Reply



Abenaki

8/19/2011 9:05 PM EDT

Could have been a resonant oscillation in the canopy and a particular wind speed and direction. In my experience with airfoils, these can grow exponentially and quickly blow up a structure.

Sign in to Reply



RogerAF

8/20/2011 12:01 PM EDT

I have seen stage rigging that was suspended from a large crane. In case of emergency it could swing the entire structure away from the audience. That was back in the early 1980s.

Sign in to Reply



Karl P.E.

8/23/2011 1:52 PM EDT

I didn't see any rigid cross bracing or guy cables that should have prevented sway or buckling of the support columns. Once the back edge dropped the next row of supports tilted forward and everything else then went forward and down to the stage platform.

Sign in to Reply



TFCSD

8/23/2011 2:56 PM EDT

From camping with pop-up canopies you find out the you need two guy wires per corner or it will collapse or fly off the same way in the wind. Another way is to put guy wires in Xs on 5 sides of the cube and nail that puppy down. Use both techniques and that canopy will not budge much. The fact that these guy wires where not put on should be looked into.

Sign in to Reply



lousmith84

9/2/2011 10:24 AM EDT

wind tunnel load testing, idiots

Sign in to Reply



Please sign in to post comment

Navigate to related information