datasheets.com EBN.com EDN.com EETimes.com Embedded.com PlanetAnalog.com TechOnline.com  
Events
UBM Tech
UBM Tech

Product Brief

3U form-factor PSU claims increased power benefits

Paul Buckley
5/30/2012 5:59 AM EDT
Pulse Electronics' 3U form-factor PSU for VPX applications is now available with optimized Positronic P47 connections and can be configured to deliver more than 400 W of power plus provide an additional high power 28 V protected output.



Pulse Electronics' 3U form-factor power supply unit (PSU) is now available with optimized Positronic P47 connections allowing delivery of more than 400 W of power.

The PSU, which is intended for military and aerospace VPX-based applications, comprises a number of Pulse Electronics’ high-reliability, planar technology power modules and can be configured to have up to five DC outputs. For example, one configuration might be: +12 V, -12 V, +5 V, +3.3 V and an auxiliary +3.3 V; all referenced to a common 0 V.

Of these output voltages, +12 V tends to be the one of which the highest power and current are now demanded, rather than the historic high current outputs for either the 5 V or 3V3, in light of the trend to down-regulate closer to processors. Through the use of optimized P47 connections, and feeding out on up to four pins rather than the single pin, some 25 A (i.e. 300 W) of peak power can be provided on the +12 V output.
 
The use of P47 connections also means the PSU can be configured to provide a 28 V protected output (rated up to 320 W). This can be used as a filtered power feed to heaters, to warm the VPX rack box when operating at low temperature extremes, or used unfiltered for powering cooling fans. Again this is only available by using an optimised pin configuration associated with the P47 connector.

The PSU’s input is a nominal 28 VDC, though its input steady state is compliant with RTCA DO-160E A(CF) – i.e. 22 to 30.3 VDC – and therefore also compliant with MIL-STD-704F (22 to 29 VDC). The unit can also be configured to be compliant with MIL-STD-1275B and DEF STAN 59-41.1 land Class ‘A’.

The modules also cope with the high transient voltage ride-through requirements of DEF STAN 61.5 part 6 issue 6 (175 V for 350 mS), which again infers input voltage losses.

Under maximum loading, the PSU’s output voltages build to within 95 percent of their respective steady states well within 250 ms of the application of the 28VDC input power. Also, a ‘Power Good’ signal indicates when all outputs are within ±7 percent of their steady state output voltage levels. This signal is opto-coupled so it can be integrated into system health monitoring circuitry. It can also be configured to give an ‘immanent over-temperature’ warning by an additional cyclic state of the ‘Power Good’.

Other standard features include: output over-current, output over-voltage and over-temperature protection along with the possibility of communication via serial bus as an option.

The unit complies with the relevant sections of RTCA DO-160E in respect of altitude, over-pressure, humidity, functional shock, random and endurance vibration, sand and dust, and conducted and radiated emissions within the confines of the sealed VPX rack configuration.

Visit Pulse Electronics at www.pulse-electronics.co.uk

Courtesy of EETimes Europe

----------------------
If you found this article to be of interest, visit
Military/Aerospace Designline where you will find the latest and greatest design, technology, product, and news articles with regard to all aspects of military, defense and aerospace. And, to register to our weekly newsletter, click here.




Please sign in to post comment

Navigate to related information

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Browse the technical library
Our technical library houses over 4,000 high-quality sponsored white papers, application notes, reference guides, use cases—all organized by company.