davebirdieee
User Rank
Author
re: How to make a Geiger counter count
davebirdieee   3/21/2015 3:19:21 AM
NO RATINGS
Found this thread just this month. Bought and assembled a very similar circuit from Electronic Goldmine. While the circuit does work, I'm having trouble understanding how some parts do indeed work. Specifically the Q3 circuit. Q3 takes a positive pulse to turn on, but a gieger tube pulse will appear as a negative pulse, at least the leading edge of it. So, it would seem that Q3 only turns on when the tube recovers (trailing edge) and/or the high voltage line charges back up. I suspect the recovery time may be faster than the charge-up time. Has anyone investigated this? Hope someone besides me is still interested in this.

Bhogan
User Rank
Author
re: How to make a Geiger counter count
Bhogan   7/9/2011 4:40:57 PM
NO RATINGS
This has been an interesting read for me. As someone who has also created a Geiger kit, I can understand some of the oddities of trouble shooting a HV circuit. The HV will travel very well through a poor conductor - excess flux on board, etc. I even discovered (unintentionally) that black foam board is conductive enough to short out the HV! Also, since the current available is so small, measuring it with a DMM will load it down so much you won't get a good reading, and the HV might stop working while the DMM is connected. At the risk of plugging a competitive product, I have written instructions that apply to measuring HV in Geiger circuits here . . . https://sites.google.com/site/diygeigercounter/home/assembly/adjusting-the-hv The should apply to any HV circuit.

Anakron
User Rank
Author
re: How to make a Geiger counter count
Anakron   6/30/2011 1:26:53 AM
NO RATINGS
Thank you so much for making this available. I got a new kit in today, revision 04/12/11LW, which did something similar. The schemos include a 100R resistor for the LED but everything else is the same. The sensitivity was almost nothing, probably a click every 3 minutes or so. I noticed that if I touched the + end of the tube with a single voltmeter probe, it stabilized and I got actual background level, about 25CPM. To my surprise I had disk shaped 1000pF/500V caps in a drawer (model military suitcase) and fitted one of them standing vertically on the outside of the transformer with one pin between T1 and Q1 to the jumper over to the (middle) case (-) of the GM tube, the other pin along the edge of the board to the cathode of the diode. I also changed R3 to 1MOhm (biggest I had in throughhole). The board now works beautifully with no double clicks. Kent (Repost from the blog)

David Ashton
User Rank
Author
re: How to make a Geiger counter count
David Ashton   6/11/2011 12:31:52 AM
NO RATINGS
I must have been thinking of another tranny I was using recently. And you'd never get this info off the kit maker. I've seen kits - and boards - where the maker has sanded the markings off the ICs to stop people copying their design...

Max The Magnificent
User Rank
Author
re: How to make a Geiger counter count
Max The Magnificent   6/10/2011 2:45:20 PM
NO RATINGS
I'm back in the office -- I can't see any markings on the tape on the transformer -- sorry...

David Ashton
User Rank
Author
re: How to make a Geiger counter count
David Ashton   6/9/2011 11:10:29 AM
NO RATINGS
As a bit of an aside, I just bought a few LCD voltmeter modules cheap from my local Dick Smith (Aussie equivalent of Tandy). They say they have 100 Megohms input impedance. So it should be possible to make a 2KV meter out of one of these with an input R of about 1 gig-ohm. Anyone know where I can get some 100 meg resistors??

David Ashton
User Rank
Author
re: How to make a Geiger counter count
David Ashton   6/9/2011 11:05:47 AM
NO RATINGS
Hmmm....smart maybe (even that is stretching it) but genius, no. I regularly surprise even myself with my own stupidity.... There is no information on T1 in the kit documentation and none of my photos show any markings. As I recall there were some markings on the transformer (on the tape covering the windings) but not sure what they were. Max?? D1 is indeed a 1N4007 - this has 1000v max reverse voltage so quite adequate for this job. If you're thinking of building one of these yourself, if you can get an inverter transformer from a small fluorescent lamp it should do. A turns ratio of about 1: 50 would be needed (9V to 400V) but do have a look at the Maxim app note at http://pdfserv.maxim-ic.com/en/an/AN3757.pdf which is for a regulated supply. Needs a few more (cheap) components, but no transformer (it's a boost switchmode supply with a voltage multiplier).

benbojangles
User Rank
Author
re: How to make a Geiger counter count
benbojangles   6/9/2011 10:02:12 AM
NO RATINGS
Dave you're a genius. Just wondering, there is no information about the transformer (T1) product number. Am I right in guessing that it is a Tamura TTC-105 Microtran? And the diode (D1) is a 1N4007?

David Ashton
User Rank
Author
re: How to make a Geiger counter count
David Ashton   6/5/2011 12:50:31 AM
NO RATINGS
Thanks Jay. The lack of DC coupling between the HV/LV did worry me as well. And I was tempted to try connecting them together. However you will note that the speaker stage is DC-coupled to the tube (ie uses the capacitance between the transformer windings for AC coupling) and if I'd DC coupled it then that would quite possibly have had other problems. I DID try putting a large-ish cap (1 uF) between the HV/LV grounds and it did not make much difference. The diode across BE of Q3 is a good idea. I'm not sure if the led going off at high counts was due to the charge on C3 or because of the capacitance (68pF) I put across the BE. As you can see form the trace above, the "event" pulse and the power supply pulses are quite different at low count rates, but at high count rates I think the event pulses would merge a bit and reduce in amplitude, so my cap would attenuate them to the point where they no longer switch Q3 on. So I'd also be keen to try Pchow's solution (lower R and no C) with a high rate source. As I said, were I designing form scratch I'd do it differently, but in this case I wanted to get the existing design going with the minimum of modification. I had such fun with this that I might buy myself a tube and try that.....

Max The Magnificent
User Rank
Author
re: How to make a Geiger counter count
Max The Magnificent   6/3/2011 6:53:18 PM
NO RATINGS
HURRAY!!! My (now-working) Geiger counter has just arrived back from David. It’s on my desk clicking away randomly – my (mildly) uranium-enriched glass marbles do seem to increase the count a bit – but I need to time things like David did to get a good feel for it. I did just borrow a 5 uSv radioactive sample from the folks in the next bay and the little scamp started clicking and flashing furiously. I also want to try it with that "No-Salt Salt" David used. I’m heading out to DAC this weekend – so I’ll take the video and write the follow-up blog when I get back. THANK YOU DAVID!!!

Page 1 / 4   >   >>


Most Recent Comments
Top Comments of the Week
Like Us on Facebook

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
EE Life
Frankenstein's Fix, Teardowns, Sideshows, Design Contests, Reader Content & More
Max Maxfield

ESC Minneapolis 2015 Sneak Peek! Baking Pis in Africa
Max Maxfield
Post a comment
One of the great things about my job is that so many interesting people get to meet me I get to meet so many interesting people (LOL). For example, I just received an email from Kurtis ...

Bernard Cole

A Book For All Reasons
Bernard Cole
1 Comment
Robert Oshana's recent book "Software Engineering for Embedded Systems (Newnes/Elsevier)," written and edited with Mark Kraeling, is a 'book for all reasons.' At almost 1,200 pages, it ...

Martin Rowe

Leonard Nimoy, We'll Miss you
Martin Rowe
5 comments
Like many of you, I was saddened to hear the news of Leonard Nimoy's death. His Star Trek character Mr. Spock was an inspiration to many of us who entered technical fields.

Rich Quinnell

Making the Grade in Industrial Design
Rich Quinnell
16 comments
As every developer knows, there are the paper specifications for a product design, and then there are the real requirements. The paper specs are dry, bland, and rigidly numeric, making ...

Special Video Section
After a four-year absence, Infineon returns to Mobile World ...
A laptop’s 65-watt adapter can be made 6 times smaller and ...
An industry network should have device and data security at ...
The LTC2975 is a four-channel PMBus Power System Manager ...
In this video, a new high speed CMOS output comparator ...
The LT8640 is a 42V, 5A synchronous step-down regulator ...
The LTC2000 high-speed DAC has low noise and excellent ...
How do you protect the load and ensure output continues to ...
General-purpose DACs have applications in instrumentation, ...
Linear Technology demonstrates its latest measurement ...
10:29
Demos from Maxim Integrated at Electronica 2014 show ...
Bosch CEO Stefan Finkbeiner shows off latest combo and ...
STMicroelectronics demoed this simple gesture control ...
Keysight shows you what signals lurk in real-time at 510MHz ...
TE Connectivity's clear-plastic, full-size model car shows ...
Why culture makes Linear Tech a winner.
Recently formed Architects of Modern Power consortium ...
Specially modified Corvette C7 Stingray responds to ex Indy ...
Avago’s ACPL-K30T is the first solid-state driver qualified ...
NXP launches its line of multi-gate, multifunction, ...
Radio
LATEST ARCHIVED BROADCAST
EE Times Senior Technical Editor Martin Rowe will interview EMC engineer Kenneth Wyatt.
Flash Poll