re: Tips & Tricks: Advancements in Powerline—A grounding experience
anne-francoise.pele   8/7/2012 8:02:16 PM
NO RATINGS
Click on the link below to check out the collection of Design Articles, Case Studies, Product How-To articles,... related to Power Line Communication that have been published on EETimes. Check back frequently. The list will be updated as new articles arrive. http://www.eetimes.com/design/smart-energy-design/4390953/Power-Line-Communication---Design-archive?Ecosystem=smart-energy-design

MarkFromNJ
User Rank
Rookie
re: Tips & Tricks: Advancements in Powerline—A grounding experience
MarkFromNJ   2/14/2012 8:47:04 AM
NO RATINGS
The problem with PLC is that it was, is, and will be unreliable. There is no way to qualify the impedance and noise environment, and as a result, no way to design a product that can be guaranteed to work. So maybe one outlet works, while the one next to it does not. Unless you have CFL bulbs in your house, in which case pretty much none of the outlets will work :( I did not take the time to look it up, but I can't imagine that the US NEC will allow this any more than the EN code in Europe does. If these signals are more than a few ma, they will screw up ground fault detection in GFI breakers and outlets, which looks for small currents on the ground leg as an indication of fault. And the high frequency in particular may disrupt sensing in AFI (arc fault interrupting) breakers that are now required for all new construction in the US. Do you think the boys and girls at Qualcomm have tested these scenarios? Sure...

EE1204
User Rank
Rookie
re: Tips & Tricks: Advancements in Powerline—A grounding experience
EE1204   2/3/2012 6:36:01 PM
NO RATINGS
PLC is pretty handy to enable networking at any AC outlet. Great to see advancements further improve the technology and performance.

RolandBHill
User Rank
Rookie
re: Tips & Tricks: Advancements in Powerline—A grounding experience
RolandBHill   12/2/2011 2:39:49 PM
NO RATINGS
Clause 9 of EN 50065-1:2011 prevent use of line to ground communication in Europe. It states; "Common-mode signalling devices may disturb the normal operation of other signalling equipment or certain residual current protection devices and may cause serious safety hazards to the user. Therefore, on common-mode signalling devices a clearly written warning (either on the product or on the leaflet) shall indicate: “Due to safety reasons the use of this product is not allowed in the residential environment. Use of common-mode signalling devices in commercial or industrial premises is allowed, provided that adequate safety checks are made in advance of installing this equipment and regularly thereafter.”

antiquus
User Rank
Rookie
re: Tips & Tricks: Advancements in Powerline—A grounding experience
antiquus   6/27/2011 3:32:29 PM
NO RATINGS
Many older American homes do not have a safety ground wired throughout the house, just line and neutral. Houses built more than 40 years ago did not have the requirement, and retrofits are prohibitively expensive.

zeeglen
User Rank
Blogger
re: Tips & Tricks: Advancements in Powerline—A grounding experience
zeeglen   6/24/2011 4:14:48 PM
NO RATINGS
One could always use the CSCJ (Carrier Sense Carrier Jam) method to discourage this. Shouldn't be too hard to breadboard a circuit that detects the first RF burst and fills subsequent AC zero crossing with a few watts of garbage. All the new HomePlug units in your neighbourhood will be quickly returned to Frys or BestBuy or wherever else they came from.

wu0f
User Rank
Rookie
re: Tips & Tricks: Advancements in Powerline—A grounding experience
wu0f   6/24/2011 12:25:29 PM
NO RATINGS
More pollution for the ether. Kiss your AM broadcast radio goodbye. Kiss your HF amateur radio goodbye. The manufactures of such devices claim that the signal is contained within the powerlines. It is not. Any disruption in the impedance will cause radiation from that point.



EE Life
Frankenstein's Fix, Teardowns, Sideshows, Design Contests, Reader Content & More
Max Maxfield

Steve Wozniak Reacts to Latest iPhone
Max Maxfield
Post a comment
Funnily enough, just a few days ago as I pen these words, I was chatting with my wife (Gina the Gorgeous) when she informed me that -- as a kid -- she had never played at making a ...

EDN Staff

11 Summer Vacation Spots for Engineers
EDN Staff
20 comments
This collection of places from technology history, museums, and modern marvels is a roadmap for an engineering adventure that will take you around the world. Here are just a few spots ...

Glen Chenier

Engineers Solve Analog/Digital Problem, Invent Creative Expletives
Glen Chenier
15 comments
- An analog engineer and a digital engineer join forces, use their respective skills, and pull a few bunnies out of a hat to troubleshoot a system with which they are completely ...

Larry Desjardin

Engineers Should Study Finance: 5 Reasons Why
Larry Desjardin
46 comments
I'm a big proponent of engineers learning financial basics. Why? Because engineers are making decisions all the time, in multiple ways. Having a good financial understanding guides these ...

Flash Poll
Top Comments of the Week
Like Us on Facebook
EE Times on Twitter
EE Times Twitter Feed

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)