Asha Ganesan
User Rank
Rookie
re: Electronics in medicine: Insulin pump design
Asha Ganesan   5/14/2013 6:07:37 PM
NO RATINGS
Hi JReyes, Could you provide more details about that device? We are eager to know.

eewiz
User Rank
CEO
re: Electronics in medicine: Insulin pump design
eewiz   5/13/2013 2:01:23 PM
NO RATINGS
interesting... which device is it? curious to know how it measures the blood sugar level? is it based on spectroscopy/imaging techniques?

JReyes
User Rank
Rookie
re: Electronics in medicine: Insulin pump design
JReyes   5/13/2013 12:14:12 PM
NO RATINGS
Hi Ewizz, My girlfriend is currently using one of these insulin pumps and there currently is a supplematary device which contunuiously monitors blood glucose level which significantly reduces the need to prick your finger. However, it's still required to test 1-3 times a day to calibrate the glucose monitor in order to relay the correct readings back to the pump. Once the blood sugar levels are sent to the pump, the pump in turn will ask the user to verify the amount of insulin to apply for correction. I think this is interesting on its own. All of this communication is done wirelessly by the way.

eewiz
User Rank
CEO
re: Electronics in medicine: Insulin pump design
eewiz   5/12/2013 2:20:18 PM
NO RATINGS
that one is not the closed loop, I intended. In the link you gave the user still needs to prick the finger/skin to get some blood on the strip to measure the glucose level. which is not automated. coming to think of it I realize that a non invasive blood sugar monitoring mechanism is needed for this to work, which mostly doesnt exist.

Asha Ganesan
User Rank
Rookie
re: Electronics in medicine: Insulin pump design
Asha Ganesan   5/12/2013 1:49:09 PM
NO RATINGS
Hi eewiz, 1. Yes, it is commercially available (https://www.accu-chekinsulinpumps.com/ipus/). This is for people with severe diabetes risks and who might have to take large dosages. The commercially available products do not have a closed loop system and the rate is adjusted through manual settings. 2. Yes, it is possible to implement a closed-loop system where we can involve the same chip to monitor current blood glucose level and accordingly adjust the flow rate. Here is a link about it:http://www.cypress.com/?rID=43661&source=header. Systems like this haven't yet come out in the medical industry.

eewiz
User Rank
CEO
re: Electronics in medicine: Insulin pump design
eewiz   5/10/2013 4:32:21 AM
NO RATINGS
oh ok.. theres no feedback mechanism to know the current blood sugar level of the patient.. it works as a linear open loop.. which is not impressive. if there was a sensor to detect the current blood sugar level and then push insulin accordingly, that wud have been interesting. For open loop drug delivery other mechanisms like micro needle patches are more convenient.

eewiz
User Rank
CEO
re: Electronics in medicine: Insulin pump design
eewiz   5/10/2013 4:20:06 AM
NO RATINGS
quite interesting.. the only problem is that people need to carry around that device. is it commercially available anywhere?



Flash Poll
EE Life
Frankenstein's Fix, Teardowns, Sideshows, Design Contests, Reader Content & More
The Engineering Life - Around the Web
Terry Cutler, CTO, Digital Locksmiths

The USB Keys in the Urinal
Terry Cutler, CTO, Digital Locksmiths
Post a comment
Security is a major obsession today, particularly as the industry makes the shift from traditional, standalone devices to the design of connected, networked systems that are “always ...

Engineer's Bookshelf
Caleb Kraft

The Martian: A Delightful Exploration of Math, Mars & Feces
Caleb Kraft
6 comments
To say that Andy Weir's The Martian is an exploration of math, Mars, and feces is a slight simplification. I doubt that the author would have any complaints, though.

Design Contests & Competitions
Caleb Kraft

Join The Balancing Act With April's Caption Contest
Caleb Kraft
58 comments
Sometimes it can feel like you're really performing in the big tent when presenting your hardware. This month's caption contest exemplifies this wonderfully.

Engineering Investigations
Caleb Kraft

Frankenstein's Fix: The Winners Announced!
Caleb Kraft
8 comments
The Frankenstein's Fix contest for the Tektronix Scope has finally officially come to an end. We had an incredibly amusing live chat earlier today to announce the winners. However, we ...

Top Comments of the Week
Like Us on Facebook
EE Times on Twitter
EE Times Twitter Feed

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)