Re: will 25G lane rate be used in switches/servers anytime soon?
a.sun   10/10/2013 2:05:52 AM
NO RATINGS
@docdivakar. Thanks for your links! I do hope you're right about that 100G will come soon in datacenters. I saw these multi-vendor 100G (4x25G) demos in the OFC of past two years. Everything is supposed to put together with the upcoming IEEE802.3bm standard.

At the end of the day, it's all about cost and power consumption. Do you know any mature CMOS or BiCMOS 25G analog ICs (driver/TIA)? I know most people uses III-V based ICs which may be a signifcant part of cost. 

krisi
User Rank
CEO
Re: will 25G lane rate be used in switches/servers anytime soon?
krisi   10/9/2013 6:07:57 PM
NO RATINGS
thank you @docdivakar, good links, I downloaded the slides...I was asked to edit a book on 100G, would you be interested in co-editing? kris.iniewski@gmail.com

docdivakar
User Rank
Manager
Re: will 25G lane rate be used in switches/servers anytime soon?
docdivakar   10/9/2013 5:40:11 PM
NO RATINGS
@a.sun: I do agree the 100G advances needed many improvements in the ecosystem. As I commented earlier in this thread, much of it has been addressed already. If you look at the third link in my comment (Plugfest), there are multiple choices of ASICs for 25G/28G including one by IBM. Granted these are not production-ready and power-optimized Silicons, they more than prove the viability of 100G.

I would argue that the migration to 100G in datacenters will come sooner than it did for the 10G. It took more than 5 generations of Silicon to get power consumptions down in 10G and it is still not low enough to make it to desktops and laptops.

MP Divakar

docdivakar
User Rank
Manager
Re: will 25G lane rate be used in switches/servers anytime soon?
docdivakar   10/9/2013 5:13:08 PM
NO RATINGS
Hi Kris, the power and cost comparisons are too preliminary at this point. The industry has made good progress in materials for high speed motherboards as well as backplane connectors.

There is a good collection of presentation of materials at one of the events we did in the Silicon Valley on the 40G/100G topic (has John D'Ambrosia's slides too):

http://comsocscv.org/showevent.php?id=1373040654

You may also want to see the following link for slides on signal integrity challenges for 100G system:

http://comsocscv.org/showevent.php?id=1372192317

Interestingly Mellanox was not in the Plugfest for CEI-25G-LR and CEI-28G-VSR in 2012:

http://www.oiforum.com/public/documents/2012_OIF_PLL_White_Paper_Feb29.pdf

MP Divakar

krisi
User Rank
CEO
Re: will 25G lane rate be used in switches/servers anytime soon?
krisi   10/8/2013 10:35:32 AM
NO RATINGS
I don't think there is any question that the whole ecosystem needs to be upgraded, yes, of course...what is the msot interestsing for me is power and cost comparisons between 10 Gb/s and 25 Gb/s lanes...anyone can provide some datapoints? Kris

a.sun
User Rank
Rookie
will 25G lane rate be used in switches/servers anytime soon?
a.sun   10/8/2013 1:25:28 AM
NO RATINGS
My understanding is going from 10G to 25G per lane is not just about the optical transceivers but the whole ecosystem. Is all the things like NICs, PCBs, connectors, etc. ready for 25G? Many Telecom systems are still using power hungry 4:10 gearbox to translate 25G optics to 10G electronics (I don't know if recently hot selling 100G DP-QPSK uses a gearbox though it comes with another power monster, DSP). In his histroy datacom technlogy always fell behind telecom due to its demands for low cost (and of course lower specs as tradeoff). Will 4x25G emerge in datacom/datacenter anytime soon? I highly doubt it.

Putting 4x25G directly on board and close to ICs may be a way to get around the whole ecosystem upgrade (like Intel is pushing, but for a different purpose :-). However, IBM's latest blue water supercomputer still adopts Avago's 12x10G optical engines on server boards. 25G has a long way to go. 

rick merritt
User Rank
Author
Re: how fast is IO?
rick merritt   10/8/2013 12:52:35 AM
NO RATINGS
@Krisi: I/O is at 25G. Engineers have been working to refine 25G serdes and module standards for several years to enable these sorts of products.

Now everyone is starting to jump in and it might be the first big entrey point for optical chip-to-chip links.

krisi
User Rank
CEO
how fast is IO?
krisi   10/7/2013 1:27:40 PM
NO RATINGS
If I read this correctly 100 Gb/s is achieved thru 4 lanes operating at 25 Gb/s...does it mean IO operate at 25 or 12.5 GHz? Kris



EE Life
Frankenstein's Fix, Teardowns, Sideshows, Design Contests, Reader Content & More
Max Maxfield

Steve Wozniak Reacts to Latest iPhone
Max Maxfield
3 comments
Funnily enough, just a few days ago as I pen these words, I was chatting with my wife (Gina the Gorgeous) when she informed me that -- as a kid -- she had never played at making a ...

EDN Staff

11 Summer Vacation Spots for Engineers
EDN Staff
20 comments
This collection of places from technology history, museums, and modern marvels is a roadmap for an engineering adventure that will take you around the world. Here are just a few spots ...

Glen Chenier

Engineers Solve Analog/Digital Problem, Invent Creative Expletives
Glen Chenier
15 comments
- An analog engineer and a digital engineer join forces, use their respective skills, and pull a few bunnies out of a hat to troubleshoot a system with which they are completely ...

Larry Desjardin

Engineers Should Study Finance: 5 Reasons Why
Larry Desjardin
46 comments
I'm a big proponent of engineers learning financial basics. Why? Because engineers are making decisions all the time, in multiple ways. Having a good financial understanding guides these ...

Flash Poll
Top Comments of the Week
Like Us on Facebook
EE Times on Twitter
EE Times Twitter Feed

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)