musthafafarhan
User Rank
Rookie
As of my understanding from this article, the shunt value range is from 0.16mO to 9.2mO (INA282). Here, It is selected as 8mO because the resistor can tolerate upto 8mO.
musthafafarhan   12/1/2015 9:59:32 PM
NO RATINGS
1 saves
 My question is, How do I find the resistor's tolerance and How did you say it is 8mO? Moreover, I still require more information about Kelvin-connection.

For example: In my design, if the shunt resistor range that I can set between 1mO to 10mO. initially if it is set as 2mO. Now I think to increase the resistor value inorder to increase the accuracy. but I dont know how much I can increase the resistor value because I dont know the resistor's tolerance. Pls Help !! Thanks a lot!

Bernie W
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
Bernie W   12/13/2012 11:56:19 PM
NO RATINGS
Thanks for a well-written and informative tutorial. Very glad I found it.

DrFPGA
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
DrFPGA   3/19/2012 4:25:18 PM
NO RATINGS
Links seem to work fine now. Several different languages supported too which is excellent.

docdivakar
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
docdivakar   3/15/2012 1:05:47 PM
NO RATINGS
Thank you for this series of four articles and the links to TINA. MP Divakar

CMathas
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
CMathas   3/14/2012 8:12:11 PM
NO RATINGS
Try now, I've reset them. Sorry for the inconvenience.

CMathas
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
CMathas   3/14/2012 8:03:33 PM
NO RATINGS
which links are you having trouble with? Both the links and printing work for me. Can you give me a bit more info so I can fix these things? Thanks, Carolyn

mclaine
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
mclaine   3/12/2012 2:40:43 PM
NO RATINGS
The print function doesn't work either

Andy_I
User Rank
Author
re: A Current Sensing Tutorial-Part IV: Layout and Troubleshooting Guidelines
Andy_I   3/9/2012 4:03:31 PM
NO RATINGS
The links don't work.



Most Recent Comments
Like Us on Facebook
EE Life
Frankenstein's Fix, Teardowns, Sideshows, Design Contests, Reader Content & More
Martin Rowe

Test Tool Finds Ethernet Wiring Errors
Martin Rowe
Post a comment
When my house was renovated several years ago, I had the electrician install network outlets in numerous places, then run the LAN cables to a wiring closet. But he didn't document the ends ...

Martin Rowe

Local Electronics Store Supplies Engineers and Hobbyists
Martin Rowe
5 comments
Rochester, N.Y. — Tucked away in this western New York city known for its optics is Goldcrest Electronics, a local store that's supplied businesses and individuals with electronic ...

Martin Rowe

How to Transform a Technology University (Book Review)
Martin Rowe
1 Comment
The Presiding Genius of the Place by Alison Chisolm. WPI, Worcester, Mass., 234 pp., 2016. Engineers love to discuss, and often criticize, engineering education. They often claim ...

Max Maxfield

Aloha from EEWeb
Max Maxfield
Post a comment
Just a few minutes ago as I pen these words, I posted this blog about this month's Cartoon Punchline Competition over on EEWeb.com.